Roof Reviver technical specifications
Tile Wash
Tilewash is a specifically designed cleaning solution for the removal of moss, moulds and lichen from concrete and Terra Cotta roof tiles.
After application, moss and lichens will deteriorate and loosen. The removal process is accelerated by water blasting.
Coverage
Total surface coverage can be achieved by using 1 Litre of Tilewash per 5 square meters of roof. Treated surfaces may become temporarily slippery. Avoid discharging into streams and avoid contact with grass and plants.
Application and equipment
Tilewash should be applied by pump driven or hand held equipment which can provide sufficient spray volume for thorough coverage and wetting.
Common application methods are:
- Motorised pump units including rotary cleaners
- Air Assisted or Airless Spray units
- Backpack spray units
- Garden hand held spray units
- Hand held watering cansRoof Reviver (Tilewash) Product Information
Tilewash is a powerful contact cleaning solution for the removal of moss, moulds and lichens on most hard surface areas.
Surface Areas For Application
- Concrete
- Weatherboards & Walls
- Tile Roofs
- Decks
- Terracotta Roofs
- Wooden & Painted Surfaces
- Translucent Roofs
- Fibro Cement
- Concrete
- Ceramic Floor & Wall Tiles
- Bricks and Blockwork
- Asbestos & Supa 6 Roofs (Warning – do not waterblast asbestos roof surfaces)
- Cobblestones & Pavers
- Paths & Driveways
Product Features
- Cleaning Solution
- Diluted for Immediate Application
- pH 12.5 – 13.5
Colour: Clear, pale yellow, mobile liquid
Appearance when dry: Clear
Odour Characteristic: Bleach odour
Storage: Store in original container. Keep upright in cool dry area. Keep lid on container when not in use.
Shelf Life (months): 12
Pack Size: 20 L @ 4% concentrate
Application Process
Remove all dirt, moss, lichen, mould and all other surface contaminants using high pressure water blasting (min. 3000 P.S.I.). After completion and time to dry, apply “Roof Reviver” Tilewash to the roof using a suitable application method, ensuring complete wetting (saturate the surface but not to the point that the product starts to run) to kill remaining spores; after approximately 1 hour (preferably overnight) hose roof thoroughly with clean water. Ensure surface is clean, dry and defect-free before proceeding with your “Roof Reviver” roof coating system.
Application Equipment
Tilewash is recommended to be applied by pump driven or hand held equipment which can provide sufficient spray volume for thorough coverage and wetting. Common application methods are; x Air Assisted or Airless Spray units x Backpack spray units x Garden hand held spray units x Hand held watering cans.
Coverage
Total surface coverage can be achieved by using 1 Litre of Tilewash per 8 m2 of roof.
Caution
Treated surfaces may become temporarily slippery; restrict traffic until dry. Avoid discharging into streams and other aquatic habitats. Avoid direct contact with grass & plants.
High-build Primer
The Primerlock High Build acrylic sealer roof coating is formulated to provide a flexible, durable coating to protect and fill badly weathered porous concrete roof tiles. It helps prevent the tile substrate from absorbing excessive amounts of Roof Reviver finishing coats and provides for a superior uniform premium finish.
Product Features
100% Acrylic Emulsion
Outstanding Adhesion
Flexible Membrane
Colour: Light Grey. Can be tinted to most colours if required.
Appearance when dry: 10-15 gloss at 60° micro tri gloss meter
Storage: Temperature Minimum 10°C, Maximum 50°C
Shelf Life (months): 12
Pack Size: 20L
Estimation
Solids Content: 65% ± 1
Dry film thickness: A minimum dry film build of 200 microns is required for effective filler build up.
Wet film thickness: 250 microns wet film to achieve 200 dry film microns.
Theoretical Coverage: 4 to 6 m2/L
Application
Weathered Porous Concrete Roof Tiles – “Roof Reviver Primerlock High Build Sealer” can only be applied once all repairs have been carried out, and the roof has been thoroughly cleaned by high pressure water blasting. Ensure that all loose and flaky dirt, dust, lichen, mould etc has been removed, so the tiles are back to a clean sound substrate We recommend using Roof Reviver Primerlock prior to the Hi-Build application as the high solids content of the product inhibits maximum penetration into the substrate.
Mixing Stir thoroughly with broad paddle to ensure product is fully incorporated.
Application Details
Maximum Relative Humidity: 75%
Application Temperature Range: 10°C – 35°C
Methods Brush, Roller, Spray – Airless spray preferred for roofing application
Cleaning Solvent: Water
Max. Volume Thinners: 5% (Water)
Nozzle Orifice: Airless spray 21-23 Thou
Fan Angle: 30° – 50°
Nozzle Pressure: Minimum 1500 psi (May vary due to size of airless machine)
Drying Characteristics
Temperature (deg.C) 10°c
- Touch dry: 2 hours
- Handle dry: 4 hours
- Full cure: 16 hours
Temperature (deg.C) 20°c:
- Touch dry: 1 hour
- Handle dry: 2 hours
- Full cure: 8 hours
Overcoating: Where possible allow dry time between coats for a minimum of two hours at 20°C & 50% relative humidity. Overcoat with “Roof Reviver” for premium results.
Primerlock
100% Acrylic Primer Sealer used to stabilise concrete roof tile substrates.
Product Features
100% Acrylic Emulsion
Excellent adhesion to concrete and masonry
Excellent: Recoatable
Colour: White
Appearance When Dry: Clear
Storage Temperature: Minimum 10°C, Maximum 50°C
Shelf Life: 18 months
Pack Size: 20L
Estimation
Solids Content (By Weight):27% ± 1
Dry film thickness: 50 microns @ 8 m/L undiluted 25 microns @ 8 m/L diluted 1:1
Wet film thickness: 110 microns per coat
Theoretical Coverage: 6-8 m2/L
Application
Concrete Roof Tiles – “Roof Reviver Primerlock” can only be applied once all repairs have been carried out, and that the roof has been thoroughly cleaned by high pressure water blasting. Ensure roof is free from all latence and contaminants.
Apply “Roof Reviver Primerlock” liberally allowing product to soak into tile surface to saturation point until it just starts to run. Avoid excessive runoff down roof and into guttering.
Mixing – Stir thoroughly with a broad paddle to ensure product is fully incorporated.
Application Details
Maximum Relative Humidity: 75%
Application Temperature Range: 10°C – 35°C
Methods: Brush, Roller, Spray – Airless spray preferred for roofing application
Cleaning Solvent: Water
Max. Volume Thinners: 5% (Water)
Nozzle Size: Airless Spray 19-21 Thou
Fan Angle: 30° – 50°
Nozzle Pressure: Between 700-1500 psi (May vary due to size of airless machine)
Drying Characteristics
Temperature (deg.C) 10°
- Touch dry: 2 hours
- Handle dry: 4 hours
- Full cure: 16 hours
Temperature (deg.C) 20°
- Touch dry: 1 hour
- Handle dry: 2 hours
- Full cure: 8 hours
Overcoating – Where possible allow dry time between coats for a minimum of two hours at 20°C & 50% relative humidity. Overcoat with “Roof Reviver” for premium results.
Top Coat Base
A High Build 100% acrylic roof coating formulated to provide a flexible, durable exterior coating to protect & enhance weathered concrete roof tiles.
Product Features
100% Acrylic Emulsion
Outstanding U.V. Exterior Durability
Flexible Membrane
Colour: Milky White. Can be tinted to a full range of colours.
Appearance when dry: 30-35 gloss at 60° micro tri gloss meter
Storage Temperature: Minimum 10°C, Maximum 50°C
Shelf Life (months): 12
Pack Size: 20L (volume content 19L)
Estimation
Solids Content: 47% ± 1
Dry film thickness: A minimum dry film build of 175 microns is required for exterior durability
Wet film thickness: Apply two coats @ 200 microns wet film to achieve dry film of 200 microns
Theoretical Coverage: 5 m2/L per coat
Application
Concrete Tile Roofs – “Roof Reviver Top Coat” can only be applied once all repairs have been carried out, and that the roof has been thoroughly cleaned by high pressure water blasting. Ensure that all loose and flaky dirt, dust, lichen, mould etc has been removed, so the tiles are back to a clean sound substrate.
Note – Disconnect down pipes and allow roof to be washed with several substantial rain falls before re-connecting and collecting water for drinking.
Mixing on site – Add Roof Reviver 1kg Pigment Additive to the Roof Reviver Top Coat Base then mix mechanically with drill on a low speed until product is fully incorporated.
Application Details
Maximum Relative Humidity: 75%
Application Temperature Range: 10°C – 35°C
Methods: Brush, Roller, Spray – Airless spray preferred for roofing application
Cleaning Solvent: Water
Max. Volume Thinners: 5% (Water)
Nozzle Orifice: Airless spray 21-27 Thou
Fan Angle: 30° – 60°
Nozzle Pressure: Between 1200-2000 psi (May vary due to size of airless machine)
Care must be taken to coat all edges & noses of tiles as well as ridging and mortar joints during application.
Drying Characteristics
Temperature (deg.C) 10°
- Touch dry: 2 hours
- Handle dry: 4 hours
- Full cure: 16 hours
Temperature (deg.C) 20°
- Touch dry: 1 hour
- Handle dry: 2 hours
- Full cure: 8 hours
Overcoating – Where possible allow dry time between coats for a minimum of two hours at 20°C & 50% relative humidity. Apply 2nd coat of “Roof Reviver” to enhance finished gloss level.
Tint (Pigment Additive)
A highly concentrated inorganic pigment that has been formulated and measured to provide a superior combination with the Roof Reviver Top Coat Base, that will enhance the appearance & protect old weathered cement tile roofs.
Product Features
100% Inorganic Pigment
Outstanding UV Stability
Excellent Opacity Level
Colour: Concentrated Pigment (from colour range)
Appearance when dry: N/A
Storage Temperature: Minimum 10°C, Maximum 50°C
Shelf Life (months): 12
Pack Size: 1 L (volume content 1Kg)
Estimations
Solids Content: 47% ± 1
Dry film thickness: N/A
Wet film thickness: N/A
Theoretical Coverage: 5 m2/L per coat (in combination with Roof Reviver Topcoat)
Application
Add to “Roof Reviver” (Topcoat Base) – can only be added to Roof Reviver Topcoat Base. 1 Kg of Roof Reviver Pigment Additive is to be dispensed into a 1 bucket of Roof Reviver Base.
Mixing on site – Add Roof Reviver 1kg Pigment Additive to the Roof Reviver Top Coat Base then mix mechanically with drill on a low speed until product is fully incorporated. If mechanical mixer is unavailable stir thoroughly with a broad paddle ensuring pigment product is fully dispersed and incorporated.
Application Details
Maximum Relative Humidity: 75%
Application Temperature Range: 10°C – 35°C
Methods: The same as Roof Reviver Top Coat Base.
Cleaning Solvent: Water (Copious quantities)
Max. Volume Thinners: 0% (Should not be thinned)
Nozzle Orifice: Airless spray 21-27 Thou
Fan Angle: 30° – 60°
Nozzle Pressure: Between 1200-2000 psi (May vary due to size of airless machine)
Care must be taken not to half dispense pigment as it will effect to opacity level of the final product. Please ensure when dispensing not to spill, as it is a very concentrated pigment additive, that will stain and may be very hard to clean up.
Drying Characteristics
Temperature (deg.C) 10°
- Touch dry: 2 hours
- Handle dry: 4 hours
- Full cure: 16 hours
Temperature (deg.C) 20°
- Touch dry: 1 hour
- Handle dry: 2 hours
- Full cure: 8 hours
Overcoating – Where possible allow dry time between coats for a minimum of two hours at 20°C & 50% relative humidity. Apply 2nd coat of “Roof Reviver” to enhance finished gloss level.
For MSDS sheets, please see the Technical page.